Mixer sensor

50,00 zł

Availability: 991 in stock

SKU: CZMP Categories: ,

The mixing circuit temperature sensor monitors the current temperature in the system and warns the controller if it is exceeded. It uses the popular KTY 81-210 as its measuring element, whose resistance changes with temperature. The data is then analysed by the controller.

The sensor is most often mounted on the supply pipe of the given circuit, e.g. radiator or underfloor heating, which ensures precise control of the heating system.

When it is needed

The mixer sensor is required when the boiler controller operates a mixing valve via the MZM-50 module or RZM-52 – for example, in a system with underfloor heating, where the circuit temperature must be lower than the boiler temperature. Without a sensor after the valve, the controller does not know what temperature the circuit actually has and cannot close or open the valve.

Compatibility

KTY 81-210 measuring element – the same type used by ProND IRYD 620, IRYD RTZ PID and TITANIC controllers in MOCEK boilers. One sensor is needed for each circuit with a valve; with the RZM-52 module (two circuits) – two sensors.

Installation

The sensor is fastened with a clamp to the supply pipe just after the mixing valve, on cleaned metal, and thermally insulated so that it measures the water temperature rather than the air in the boiler room. The cable can be extended.

Unit weight 5 kg
Accessories

sensor

Manufacturer
MOCEK SPÓŁKA JAWNA
MOCEK
Kowalew, ul. Kościelna 13, 63-300 Pleszew, Poland
biuro@kotly-mocek.pl · +48 509 798 979 · https://kotly-mocek.pl
Product identifier
Mixer sensor
SKU: CZMP

Warning

  • Replace only when the boiler has cooled downThe boiler must be shut down, cooled down and disconnected from the power supply.
  • Heavy cast iron parts with sharp edgesWear gloves; for larger parts, ask another person for help.
  • Choose the part that matches your boiler modelCheck the model and the chamber size — an unsuitable part impairs combustion and may damage the boiler.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

FAQ

When is a mixer sensor needed?

When the boiler controller operates a mixing valve via an MZM-50 or RZM-52 module, for example in a system with underfloor heating. Without the sensor, the controller doesn't know the circuit temperature and cannot open or close the valve correctly.

How many sensors does the installation need?

One sensor is needed for each circuit with a valve. With the RZM-52 module, which supports two circuits, two sensors are needed.

How do I install the mixer sensor?

The sensor is fixed with a clamp to a cleaned supply pipe just after the mixing valve and thermally insulated, so that it measures the water temperature rather than the air in the boiler room. The cable can be extended.

Which controllers does the sensor work with?

The KTY 81-210 sensing element is the same type used by the ProND IRYD 620, IRYD RTZ PID and TITANIC controllers in MOCEK boilers.